Create or import a settings file containing set preferences. This may be useful when exporting settings to a new installation, sharing settings with other DTX Studio Clinic users, or making a backup.
Some settings cannot be exported because they are different on other workstations: possibly unique folder paths, hardware-specific settings (e.g. hardware-accelerated rendering), TWAIN devices and more.
The following data can be shared and imported:
Custom guided acquisition templates with a specific image acquisition order for the guided acquisition workflow of intraoral X-ray images (intraoral sensors or PSP devices). This template is saved on the workstation.
Settings:
Category | Setting |
General | Short date format |
Long date format | |
Time format | |
Language | |
Practice | Tooth numbering system |
Mandatory patient ID | |
Use DIN 6862-2 standard | |
Institution name | |
Institution address | |
Institutional department name | |
Image settings | All settings, including default capture template* |
Storage | Local storage (number of patients) |
DTX Studio Implant | Application path |
Export path | |
Medit Scan | Data storage location |
Quick Launch | Applications |
Parameters | |
Export | Practice logo path |
Custom template | |
MagicAssist | Detect tooth numbers* |
PMS | All settings |
Performance | Fast launch DTX Studio Clinic |
Launch DTX Studio Home on startup | |
Clinical picture resolution | |
Devices | Sensor support |
Camera freeze duration* | |
Export image | All settings |
DTX Studio Clinic preferences:
Category | Setting |
Workspace | Default image size |
Available workspaces | |
Image settings | All settings |
3D viewer | Background settings |
Tools | Spotlight mode |
The following user-specific settings are not included in the exported settings file. However, on the same workstation, they are saved for each DTX Studio Clinic user individually.
DTX Studio Home settings:
Category | Setting |
Image settings | Default capture template |
Export | Practice logo |
Screenshots location | |
Export directory | |
MagicAssist | 3D data detection |
Detect tooth numbers | |
Devices | Intraoral camera freeze duration |
DTX Studio Clinic preferences:
Category | Setting |
3D viewer | Default background image setting |
Default 3D background image | |
Default 3D background color | |
Workspace | Recent images: number of days |
Right-click behavior |
To export all settings to a file:
Open the Settings dialog.
Click Share settings.
Click Browse to set the export location.
Click Save.
Click Export.
To import all settings from a file:
Open the Settings dialog.
Click Share settings.
Click Browse to go to the location where the settings files (*.set) have been stored.
Click Open.
Click Import.